Mitsubishi Electronics FR-F700 Marine Battery User Manual


 
Features
Standard
Specifications
Outline Dimension
Drawings
Terminal Connection
Diagram
Terminal Specification
Explanation
Explanation of the
Operation Panel
(FR-DU07)
Parameter List
Explanations of
Parameters
Protective Functions
Option and
Peripheral Devices
Precautions for
Operation/Selection
Precautions for Peripheral
Device Selection
Application to Motor
Warranty
Main differences and
compatibilities with
the FR-F500(L) series
International FA center
Connection with
Peripheral Devices
Why can the inverter
save energy?
1
5
7
9
16
19
21
28
47
49
59
63
64
65
66
(1) Adjustable 5 points V/F
21
Evolution of the inverter for fan and pump applications,
energy savings for buildings and factories as a whole
Evolution of the inverter for fan and pump applications,
energy savings for buildings and factories as a whole
[Ex. of Blower Operation Characteristics]
[Ratio of Motor Power Consumption during Acc./Dec.]
•Achieved a higher level of energy savings during acc./dec. to say
nothing of during constant speed.
FR-F700
Conventional model(FR-F500)
Motor Lord Torque (%)
(1)
Upgrade of the renown Optimum Excitation Control!!
•The effect of energy savings can be confirmed using the
operation panel, output terminal (FM, AM terminal) and
via networks with the newly developed energy saving
monitor.
(2)
The effect of energy savings is obvious
Ex. of Power Savings
Monitor Display
[Energy Saving Monitor List]
Power saving monitor (kW)
Power saving rate (%)
Power saving amount (kWh)
Power saving amount charge ($)
Power saving average value (kW)
Power saving rate average value (%)
Power saving charge average value ($)
Annual power saving amount (kWh)
Annual power saving amount charge ($)
01020304050
100
90
M
O
R
E
S
A
V
I
N
G
S
!
Driving of the Mitsubishi 400V 4 poles
45kW motors comparison
12%
Commercial
power
operation
Frequency (Hz)
V/F control
01020304050 60
20
40
60
80
100
Optimum
excitation
control
6%
Power Consumption (%)
Power Consumption Ratio (%)
A
Photo:FR-F740-5.5K
RS-485 terminal
Combed shaped wiring cover
Removable terminal block
Easy operation
with the setting
dial of the
operation panel
Built-in
EMC filter
AU/PTC
switchover switch
Connector
with/without
EMC filter
RS-485 communication is
possible with PU connector
Easy replacement with
the cooling fan cassette!!
E
G
C
H
A
B
D
F
BEST
MATCH
•Possible to set the torque
pattern that is optimum for the
machine's characteristic
•Possible to expect even more
energy savings with optimum
excitation control and optimum
V/F pattern working together
0
V/F5
V/F4
V/F3
V/F2
V/F1
Voltage
Base
Frequency
V/F Characteristic
Torque
characteristic
curves
V/F
pattern
Frequency
Base
Frequency
Voltage
(2) Enhanced PID function
Energy savings in low speed region ... PID shutoff (sleep control) function
Shorter PID startup time ... PID automatic switchover function
Monitor of set point/measured value/deviation possible ... PID monitor
Convenient for HVAC usage ... forward/reverse operation switchover
is simple with an external signal
Corresponds to a wide range of detectors ... set point and measured value
for PID input can either be voltage (0 to 5V/0 to 10 V) or current (4 to 20mA)
(3)
Adoption of the original operation continuation
at instantaneous power failure function
•Operation continues without
the motor coasting when an
instantaneous power failure
occurred in fan and blower
applications.
*The inverter may trip and the motor may
coast depending on the load condition.
IPF
Input
Power Supply
Output
Frequency
Deceleration
Reacceleration
When power is restored during deceleration
•Restart can be made without stopping the
motor when the motor is coasting due to an
instantaneous power failure.
(4) Restart after instantaneous
power failure function
•Smoothly restarts a motor that is rotating even in
the opposite direction due to the windmill effect.
(5) Flying start
Possible to avoid regeneration overvoltage alarm by
automatically increasing the frequency and continue
operation if the fan happens to rotate faster due to
the effect of another fan in the same duct.
(6)
Regeneration avoidance function
Switchover to commercial power-supply operation is
simple using R1 and S1 terminals of the control circuit
and commercial power-supply switchover sequence.
(8) Commercial power-supply
switchover sequence
•Protection of the motor can be certain since the
built-in PTC of the motor can be input directly in
addition to the electronic thermal relay function.
PTC thermistor input…Positive Temperature Coefficient Thermistor
(7) PTC thermistor input
B
Adoption of newly developed long life cooling fan (design life of 10 years*
1
)
Longer operating life is further enhanced with the use of ON/OFF control of cooling fan.
•Adoption of long life capacitor (design life of 10 years*
1, 2
)
A capacitor with specification of 5000 hours at 105˚C ambient temperature is adapted.
*1
Ambient temperature: yearly average 40˚C (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Since the design life is a calculated value, it is not a guaranteed value.
*2 Output current: 80% of the rated current of Mitsubishi standard 4P motor
(1)
Operating life of parts are further lengthened
Degrees of deterioration of main circuit capacitor, control circuit
capacitor or inrush current limit circuit can be diagnosed by monitor.
•Trouble can be avoided with the self-diagnostic alarms* that is
output when the life span is near.
*Any of alarm for main circuit capacitor, control circuit capacitor, inrush current limit
circuit and cooling fan can be output.
(2)
State of the art longevity diagnostic method
•Maintenance timer output function can also inform of
maintenance time for peripheral equipments.
Average output current value and maintenance timer value are output as pulses.
(3) Maintenance timer
(4) Update is also easy
¥When exchanging the inverter, the control
circuit terminals can be exchanged.
The removable terminal block of the FR-
F500 series can be used.
(The terminal block of the FR-F700 series is compatible with
that of the FR-F500 series.
Note that some functions of the FR-F700 series are restricted
when using the terminal block of the FR-F500 series.)
Removable terminal block
A
C
D
¥Wiring cover can be reinstalled after wiring.
(200V class 22K or less, 400V class 30K or less)
Wiring is easy with the combed shaped wiring cover
¥Parameter setting for multiple inverters is simple by
copy with the operation panel.
Possible to copy parameters with operation panel
(5) Improved workability
¥The installation position of the cooling fan is in the
upper portion of the inverter.
Fan replacement is easily done without having to
remove the main circuit wires.
Easy replacement of cooling fan
¥
Alarm history (alarm details and frequency, current, voltage
and cumulative energization time at time of alarm
occurrence) can be displayed on the operation panel and
the cause of a trouble can be checked.(up to 8 past alarms)
Alarm history
FR-F500 series
FR-F700 series
RELIABLE
EASY
I
I