Mitsubishi Electronics FR-F700 Marine Battery User Manual


 
27
867
AM output filter 0 to 5s 0.01s 0.01s 32
872
Input phase failure protection selection 0, 1 1 0 42
Regeneration
avoidance function
882
Regeneration avoidance operation
selection
0, 1 1 0 45
883
Regeneration avoidance operation level 300 to 800V 0.1V 380V/760V*1 45
884
Regeneration avoidance at deceleration
detection sensitivity
0 to 5 1 0 45
885
Regeneration avoidance compensation
frequency limit value
0 to 10Hz, 9999 0.01Hz 6Hz 45
886
Regeneration avoidance voltage gain 0 to 200% 0.1% 100% 45
Free
parameter
888
Free parameter 1 0 to 9999 1 9999 45
889
Free parameter 2 0 to 9999 1 9999 45
Energy saving monitor
891
Cumulative power monitor digit shifted
times
0 to 4, 9999 1 9999 32
892
Load factor 30 to 150% 0.1% 100% 45
893
Energy saving monitor reference (motor
capacity)
0.1 to 55/0 to 3600kW*2 0.01/0.1kW*2
Inverter rated
capacity
45
894
Control selection during commercial
power-supply operation
0, 1, 2, 3 1 0 45
895
Power saving rate reference value 0, 1, 9999 1 9999 45
896
Power unit cost 0 to 500, 9999 0.01 9999 45
897
Power saving monitor average time 0, 1 to 1000h, 9999 1 9999 45
898
Power saving cumulative monitor clear 0, 1, 10, 9999 1 9999 45
899
Operation time rate (estimated value) 0 to 100%, 9999 0.1% 9999 45
Calibration parameters
C0
(900)
FM terminal calibration
46
C1
(901)
AM terminal calibration
46
C2
(902)
Terminal 2 frequency setting bias
frequency
0 to 400Hz 0.01Hz 0Hz 39
C3
(902)
Terminal 2 frequency setting bias 0 to 300% 0.1% 0% 39
125
(903)
Terminal 2 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 39
C4
(903)
Terminal 2 frequency setting gain 0 to 300% 0.1% 100% 39
C5
(904)
Terminal 4 frequency setting bias
frequency
0 to 400Hz 0.01Hz 0Hz 39
C6
(904)
Terminal 4 frequency setting bias 0 to 300% 0.1% 20% 39
126
(905)
Terminal 4 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 39
C7
(905)
Terminal 4 frequency setting gain 0 to 300% 0.1% 100% 39
989
Parameter copy alarm release 10/100 1 10/100*2 -
PU
990
PU buzzer control 0, 1 1 1 46
991
PU contrast adjustment 0 to 63 1 58 46
Clear
parameters
Pr.CL
Parameter clear 0, 1 1 0 46
ALLC
All parameter clear 0, 1 1 0 46
Er.CL
Alarm history clear 0, 1 1 0 46
PCPY
Parameter copy 0, 1, 2, 3 1 0 46
*1 The initial value differs according to the voltage class. (200V class / 400V class)
*2 Differ according to capacities. (55K or less/75K or more)
Function
Parameters
Name Setting Range Increments Initial Value
Refer to
page