Reference Manual
00809-0100-2230, Rev BB
August 2014
Rosemount 2230
A-4
Appendix A. Reference Data
A.3 ORDERING
INFORMATION
Model (Pos 1) Product Description Note
2230 Graphical Field Display
Code (Pos 2) Default Language Note
E English
S Spanish
G German
F French
P Portuguese
I Italian
C Chinese
Code (Pos 3) Tankbus: Power and Communication Note
F Bus powered 2-wire FOUNDATION™ fieldbus (IEC 61158)
Code (Pos 4) Software Note
S Standard
Code (Pos 5) Hazardous Location Certification Note
I1 ATEX Intrinsic Safety
I2 Brazil Inmetro Intrinsic Safety
I5 FM-US Intrinsic Safety
I6 FM-Canada Intrinsic Safety
I7 IECEx Intrinsic Safety
KA ATEX Intrinsic Safety+FM-US Intrinsic Safety
KC ATEX Intrinsic Safety+IECEx Intrinsic Safety
KD FM-US Intrinsic Safety+FM-Canada Intrinsic Safety
NA No Hazardous Location Certification
Code (Pos 6) Custody Transfer Type Approval Note
R OIML R85 E performance certification
C
(1)
PTB Eich (German W&M)
N NMi (the Netherlands W&M)
0 None
Code (Pos 7) Housing Note
A Standard enclosure Polyurethane-covered aluminium. IP 66/67
Code (Pos 8) Cable/Conduit Connections Note
1 1/2–14 NPT and 3/4-14 NPT Adapters Female thread. Includes 2 plugs and 3 adapters
2 M20 x 1.5 and M25 x 1.5 Female thread. Includes 2 plugs
G Metal Cable Glands (M20 x 1.5 and M25 x 1.5) Min. temperature -20˚C (-4˚F). ATEX / IECEx
Exe approved. Includes 2 plugs
E Eurofast Male, M20 x 1.5 and M25 x 1.5 3 plugs included
M Minifast Male, M20 x 1.5 and M25 x 1.5 3 plugs included
Code (Pos 9) Mechanical Installation Note
W Wall installation kit included
P Mounting kit for both wall and pipe installation (1-2 in. vertical and horizontal pipes)
Code Options – none or multiple selections are possible Note
ST Engraved SST tag plate Provide tag information in order
Model Code Example: 2230 - E F S I1 0 A 1 W - ST
(1) Requires 5900S Radar Level Gauge and 2410 Tank Hub with corresponding Custody Transfer Type Approval