4-37
Rosemount 2230
Section 4. Configuration and Operation
10. Configure all the MAO Blocks that are used. Ensure that unused MAO
block inputs are unconfigured, i.e. that there are no tank numbers or tank
parameters configured for these inputs.
11. Click the Send button to store the current configuration in the device
configuration database.
12. Once the MAO Block mapping is finished, you may proceed with
configuration of custom parameters if needed. Return to the Guided
Setup window and click the Custom Parameters button to open the
Custom Parameters window.
13. The Custom Parameters window lets you specify names for various
custom parameters:
The Long Custom Parameter Name is used for the Single Value view
and the Two Values View on the 2230 Display. It may be up to 20
characters long.
The Short Custom Parameter Name is used for the Four Values View
on the 2230 Display. It may be up to four characters long.
14. Click the Send button to store the current configuration in the device
configuration database.
15. Proceed with configuration of custom units by clicking the Custom Units
button.