Emerson 2230 Marine Sanitation System User Manual


 
Reference Manual
00809-0100-2230, Rev BB
August 2014
5-13
Rosemount 2230
Section 5. Service and Troubleshooting
5.4 RESOURCE BLOCK
Table 5-9. Resource Block
BLOCK_ERR messages
5.5 TRANSDUCER BLOCK
Error conditions that may appear in the Transducer block.
Table 5-10. Transducer Block
BLOCK_ERR messages
Condition Name Description
Block configuration error Configuration Error is used to indicate that you have selected
an item in FEATURES_SEL or CYCLE_SEL that was not set
in FEATURES or CYCLE_TYPE, respectively
Simulate active This indicates that the simulation switch is in place. This is not
an indication that the I/O blocks are using simulated data
Power up
Out of Service The actual mode is Out Of Service
Device Fault State Set and cleared using SET_FSTATE and CLR_FSTATE
Condition Name Description
Other error Set whenever XD_ERROR is non-zero. See also “Service
Tools In AMS” on page 5-17.
Out of Service The actual mode is out of service.