Connection diagram, PLG cable, PU
connector
(2) Setting the number of PLG pulses and PLG rotation direction
Set the following parameters according to the PLG specification.
!
The rotation direction monitor of the parameter unit displays the rotation direction of the encoder,
refer to the following table.
!
When using a conventional motor and a PLG cable (FR-VCBL/FR-JCBL), refer to the
Instruction Manual (detailed).
Parameter Name Factory Setting Setting Range Remarks
851 Number of PLG pulses 2048 0 to 4096
Extension
mode
852 PLG rotation direction 1 0, 1
Pr. 852 Setting Relationship between the motor and PLG
0
1
(factory setting)
REMARKS
By setting "1" in Pr.160 "extended function selection", Pr. 851 and Pr. 852 are made valid.
The number of PLG pulses should be between 1000 and 4096.
Forward rotation is clockwise rotation
when viewed from A.
A
PLG
CW
Forward rotation is counterclockwise rotation
when viewed from A.
CCW
A
PLG
A
PLG