RUN AND OPERATION
3
Basic operation (Speed setting, run,
speed meter adjustment)
!
External jog operation
Keep the start switch (STF or STR) on to perform operation, and turn it off to stop.
1)Set Pr. 15 "jog speed setting" and Pr. 16 "jog acceleration/deceleration time".
2)Select the external operation mode.
3)Switch on the jog signal. Keep the start switch (STF or STR) on to perform operation.
Assign the terminal used for the jog signal in any of Pr. 180 to Pr. 183 and Pr. 187
(input terminal function selection). (Refer to page 61.)
(3) Choosing external/PU combined operation mode 1 (operation using the external start
signal and operation panel)
! When setting the start signals from outside inverter (e.g. switches or relays) and the run-
ning speed from the operation panel (Pr. 79=3)
Operation command : start signal connected outside
Speed setting : of PU or multi-speed command (multi-speed command has priority)
For multi-speed command, refer to Pr.4 to Pr.6 on page 50.
REMARKS
When setting the start signal from the PU and speed setting signal from outside inverter, set
"
4
"
(
combined operation mode 2
)
in Pr.79
"
operation mode selection
"
.
2.
4.
3.
5.
1.
ON
ON
FR-DU04
-1
CONTROL PANEL
Hz/r
MON EXT PU
A
V
REV FWD
FR-DU04
-1
CONTROL PANEL
Hz/r
MON EXT PU
A
V
REV FWD
Power on
Switch power on.
Operation mode selection
Set "3" in Pr. 79 "operation mode selection".
The combined operation mode is selected and the operation
status indication "EXT" and "PU" are lit.
Flicker
Start
Turn on the start switch (STF or STR).
The operation status indication "FWD" or "REV" is lit.
REMARKS
The motor does not start if both the forward and
reverse rotation switches are turned on. If both
switches are turned on during operation, the motor
decelerates to a stop.
Set the speed in the speed setting mode
Forward
rotation
Reverse
rotation
Running speed setting
Using , of PU, set the running speed to 150r/min
The operation command indication FWD or REV is lit.
Stop
Turn off the start switch (STF or STR).
The motor decelerates to stop.
Operation
Display
OFF
Forward
rotation
Reverse
rotation
FR-DU04
-1
CONTROL PANEL
Hz/r
MON EXT PU
A
V
REV FWD
When Pr. 75 "PU stop selection" = "14 to 17",
CAUTION
and press .
SET
The operation status indication "FWD" or "REV" is lit.
SET REV FWD
STOP
RESET
is valid.
(Refer to page 52 for details of Pr.79.)
(Refer to page 27.).