PARAMETERS
Parameter
5
Function list (Extended function
parameters)
Remote output
495
Remote output
selection
You can turn on/off the inverter output.
0: Non-latch
1: Latch
0
"
""
""
""
""
""
"
496 Remote output data 1
You can set the output signal data of the inverter.
0 to 4095
0 "
""
""
""
""
""
"
497 Remote output data 2
0
"
""
""
""
""
""
"
Operation selection functions
800
Control system
selection
0 to 5, 20 0
"
""
""
""
""
""
"
801
Torque characteristic
selection
You can select the torque characteristic when choosing the motor provided with PLG.
0: Cycle
1: Continuous
1
"
""
""
""
""
""
"
802
Pre-excitation
selection
You can select zero speed control or servo lock when the LX signal turns on at a stop.
0: Zero speed control
1: Servo lock
0
"
""
"
×
"
""
"
803
Constant output
region torque
characteristic
selection
You can select how to provide a torque command in the constant output region.
0: Constant output reference
1: Constant torque reference
0
"
""
""
""
""
""
"
804
Torque command
right selection
Select the torque command right.
0: No. 3 terminal analog input
1: Digital input from parameter (Pr. 805, Pr. 806)
2: Pulse train command input (when the FR-V5AP is fitted)
0
×
"
""
"
×
805
Torque command
value (RAM)
You can set the torque command value in the parameter. (RAM)
600 to 1400%
1000%
×
"
""
"
×
806
Torque command
value
(RAM, E
2
PROM)
You can set the torque command value in the parameter. ( RAM, E
2
PROM)
600 to 1400%
1000%
×
"
""
"
×
807
Speed restriction
selection
You can select the speed restriction command input for torque control.
0: Same as speed setting for speed control
1: Control restrictions for individual rotation directions
2: No. 1 terminal analog input
0
×
"
""
"
×
808
Forward rotation
speed restriction
Set the speed restriction in forward rotation direction individually according to the
rotation direction.
0 to 3600r/min
1500r/min
×
"
""
"
×
809
Reverse rotation
speed restriction
Set the speed restriction in reverse rotation direction individually according to the
rotation direction.
0 to 3600r/min, 9999
9999
×
"
""
"
×
Control system functions
810
Torque restriction
input method
selection
Set whether to make torque restriction using internal parameter values or analog
voltage. (0: Internal, 1: External)
0
"
""
"
×
"
""
"
Function
Parameter
Name Outline
Factory
Setting
Cus-
tomer
Set-
ting
At-a-glance Guide to Func-
tions
"
""
": Usable function
×: Unusable function
* :
Functions that can be used
for parameter-set position con-
trol
Vector Control
Speed
control
Torque
control
Position
control