PARAMETERS
Parameter
5
Function list (Extended function
parameters)
Sub functions
156
Stall prevention
operation selection
You can make setting to prevent the inverter from an overcurrent trip (prevent the fast-
response current restriction from being activated) and/or set the OL signal output delay
if stall prevention is activated by an overcurrent or an excessive current flows due to
sudden fluctuation of load, ON-OFF of the running inverter output side or the like.
1
"
""
""
""
""
""
"
157
OL signal output
timer
Set whether to output the overload alarm signal (OL signal) immediately or after a
preset period of time when an overload status has occurred.
0 to 25s, 9999
0
"
""
""
""
""
""
"
Display functions
158
DA2 terminal function
selection
Select the monitor output DA2 data.
1: Speed
2: Output current
3: Output voltage
5: Preset speed
6: Output frequency
7: Motor torque
8: Converter output voltage
9: Regenerative brake duty
10: Electronic thermal relay load factor
11: Output current peak value
12: Converter output voltage peak value
17: Load meter
18: Motor excitation current
21: Reference output
32: Torque command
33: Torque current command
34: Motor output
36: Torque monitor (driving/regenerative polarity switching)
1
"
""
""
""
""
""
"
Automatic restart after
instantaneous power failure
160
Extended function
selection
0,1 0
"
""
""
""
""
""
"
162
Automatic restart
after instantaneous
power failure
selection
Valid during V/F control
You can select the method for automatic restart after instantaneous power failure.
0: With speed search
1: Without speed search
10: Speed search initiated per start
0
×××
163
First cushion time for
restart
Set the first cushion time for restart (0 to 20s), first cushion voltage for restart (0 to
100%) and restart current restriction level (0 to 200%) when a slight overload status
has occurred at an automatic restart after instantaneous power failure.
0s
×××
164
First cushion voltage
for restart
0%
×××
165
Restart current
restriction level
150%
×××
Function
Parameter
Name Outline
Factory
Setting
Cus-
tomer
Set-
ting
At-a-glance Guide to Func-
tions
"
""
": Usable function
×: Unusable function
* :
Functions that can be used
for parameter-set position con-
trol
Vector Control
Speed
control
Torque
control
Position
control
Setting
Fast-Response Current
Restriction
"
""
"
: Activated
!
!!
!
: Not activated
OL Signal Output
"
""
"
: Operation continued
!
!!
!
: Operation not continued
0
"
""
""
""
"
1
!
!!
!
"
""
"
2
"
""
""
""
"
3
!
!!
!
"
""
"
4
"
""
""
""
"
5
!
!!
!
"
""
"
6
"
""
""
""
"
7
!
!!
!
"
""
"
8
"
""
""
""
"
9
!
!!
!
"
""
"
10
"
""
""
""
"
11
!
!!
!
"
""
"
12
"
""
""
""
"
13
!
!!
!
"
""
"
14
"
""
""
""
"
15
!
!!
!
"
""
"
16
"
""
"
!
!!
!
17
!
!!
!!
!!
!
18
"
""
"
!
!!
!
19
!
!!
!!
!!
!
20
"
""
"
!
!!
!
21
!
!!
!!
!!
!
22
"
""
"
!
!!
!
23
!
!!
!!
!!
!
24
"
""
"
!
!!
!
25
!
!!
!!
!!
!
26
"
""
"
!
!!
!
27
!
!!
!!
!!
!
28
"
""
"
!
!!
!
29
!
!!
!!
!!
!
30
"
""
"
!
!!
!
31
!
!!
!!
!!
!
100
Driving
"
""
""
""
"
Regener-
ation
!
!!
!
"
""
"
101
Driving
!
!!
!
"
""
"
Regener-
ation
!
!!
!
"
""
"