Mitsubishi Electronics FR-V500 Marine Battery User Manual


 
55
PARAMETERS
Function list (Extended function
parameters)
Operation selection functions
29
Acceleration/
deceleration pattern
Determines the frequency changing pattern for acceleration/deceleration.
0: Linear acceleration/deceleration
1: S-pattern acceleration/deceleration A
2: S-pattern acceleration/deceleration B
3: Backlash compensation acceleration/deceleration
4: S-pattern acceleration/deceleration C
0
"
""
""
""
"
×
30
Regenerative
function selection
Set when using the FR-ABR, FR-HC or FR-CV option for frequent start/stop operation.
0: Internal brake resistor, brake unit
1: Brake resistor (FR-ABR)
2: High power factor converter (FR-HC), power return common converter (FR-CV)
0
"
""
""
""
""
""
"
31 Speed jump 1A
Set the speed ranges you want to avoid during constant-speed operation to avoid
resonance with the machine.
0 to 3600r/min, 9999
9999
"
""
""
""
"
×
32 Speed jump 1B
9999
"
""
""
""
"
×
33 Speed jump 2A
9999
"
""
""
""
"
×
34 Speed jump 2B
9999
"
""
""
""
"
×
35 Speed jump 3A
9999
"
""
""
""
"
×
36 Speed jump 3B
9999
"
""
""
""
"
×
37 Speed display
You can set the speed as a machine speed.
0, 1 to 9998
0
"
""
""
""
""
""
"
Output terminal
functions
41
Up-to-speed
sensitivity
You can adjust the output signal on/off range when the output speed reaches the
running speed.
0 to 100%
10%
"
""
"
××
42 Speed detection
You can adjust the speed detected.
0 to 3600r/min
300r/min
"
""
""
""
""
""
"
43
Speed detection for
reverse rotation
You can change the speed detection level for forward or reverse rotation in vertical lift,
transfer and other applications.
0 to 3600r/min, 9999
9999
"
""
""
""
""
""
"
Second functions
44
Second acceleration/
deceleration time
Second function of the acceleration/deceleration time set in Pr. 7, Pr. 8.
0 to 3600s/0 to 360s
5s
"
""
""
""
"
×*
45
Second deceleration
time
Second function of the deceleration time set in Pr. 8.
0 to 3600s/0 to 360s, 9999
9999
"
""
""
""
"
×*
Output terminal
functions
50
Second speed
detection
Set the speed at which the FB2 signal is output.
0 to 3600r/min
750r/min
"
""
""
""
""
""
"
Display functions
52
DU/PU main display
data selection
You can select the DU/PU main display data.
0, 100: Speed, output current, output voltage, alarm display
5: Preset speed
6: Output frequency
7: Motor torque
8: Converter output voltage
9: Regenerative brake duty
10: Electronic thermal relay load factor
11: Output current peak value
12: Converter output voltage peak value
17: Load meter
18: Motor exciting current
19: Position pulse
20: Cumulative energization time
23: Actual operation time
24: Motor load factor
32: Torque command
33: Torque current command
34: Motor output
35: Feedback pulse
38: Trace status
0
"
""
""
""
""
""
"
53
PU level display data
selection
You can select the PU level display data.
0: No monitor
1: Speed
2: Output current
3: Output voltage
5: Preset speed
6: Output frequency
7: Motor torque
8: Converter output voltage
9: Regenerative brake duty
10: Electronic thermal relay load factor
11: Output current peak value
12: Converter output voltage peak value
17: Load meter
18: Motor exciting current
1
"
""
""
""
""
""
"
Function
Parameter
Name Outline
Factory
Setting
Cus-
tomer
Set-
ting
At-a-glance Guide to Func-
tions
"
""
": Usable function
×: Unusable function
* :
Functions that can be used
for parameter-set position con-
trol
Vector Control
Speed
control
Torque
control
Position
control