Mitsubishi Electronics FR-V500 Marine Battery User Manual


 
26
Names and functions of the opera-
tion panel
RUN AND OPERATION
3
3.3 Names and functions of the operation panel
With the operation panel (FR-DU04
-1
), you can perform operation, set the speed, monitor the operation command
display, set parameters, display an error, and copy parameters.
!
Key indication
!
Unit indication, operation status indication
REMARKS
The ON of the LED is indicated by", and OFF by
!
.
Key Description
Select the operation mode or setting mode.
Determine the speed or parameter setting.
Used to increase or decrease the running speed consecutively. Hold down this key to change the
speed.
Press this key in the setting mode to change the parameter setting consecutively.
Forward rotation command key.
Reverse rotation command key.
Used to stop operation.
Used to reset the inverter when the protective function (major fault) is activated to stop the output.
Indication Description
Hz/r Lit to indicate the output speed.
A Lit to indicate the current.
V Lit to indicate the voltage.
MON Lit in the monitor display mode.
PU Lit in the PU operation mode.
EXT Lit in the external operation mode.
FWD Flickers during forward rotation.
REV Flickers during reverse rotation.
Hz/r
A
V
MON EXT PU
Operation status indication
Forward rotation key
Reverse rotation key
Unit indication
Hz/r (motor speed)
A (current)
V (voltage)
Up/down keys
Stop/reset key
isplay
ED 4 digits
Mode key
etting key
CONTROL PANEL
FWD
MODE
SET
REV FWD
STOP
RESET
REV
MODE
SET
FWD
REV
STOP
RESET