Syntax
download storageArray physicalDiskFirmware file= ”filename”
[file=”
filename2”... file=”filenameN”]
Parameter
Parameter Description
file
File path and name of the file that contains the
firmware. Valid file names must end with a .dlp
extension. You must put quotation marks (" ")
around the file name.
Additional Information
When you run this command, you can download more than one firmware image file to the physical disks
in a storage array. The number of firmware image files that you can download depends on the storage
array. The MD storage management software returns an error if you try to download more firmware
image files than the storage array can accept.
You can schedule downloads for multiple physical disks at the same time, including multiple physical
disks in a redundant disk group. Each firmware image file contains information about the physical disk
types on which the firmware image runs. The specified firmware images can be downloaded only to a
compatible physical disk. Use the download physicalDisk firmware command to download a
firmware image to a specific physical disk.
The download storageArray physicalDiskFirmware command blocks all I/ O activity until a
download try has been made for each candidate physical disk or you run the stop storageArray
downloadPhysicalDiskFirmware command. When the download storageArray
physicalDiskFirmware
command finishes downloading the firmware image, each candidate physical
disk shows the download status for each physical disk. One of these statuses is returned:
• Successful
• Unsuccessful With Reason
• Never Attempted With Reason
Download Storage Array NVSRAM
Description
This command downloads NVSRAM values for the storage array RAID controller module.
Syntax
download storageArray NVSRAM file="filename"
[healthCheckMelOverride=(TRUE | FALSE)]
224