Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-69
06-16
Present Fault Record
06-17
Second Most Recent Fault Record
06-18
Third Most Recent Fault Record
06-19
Fourth Recent Fault Record
06-20
Fifth Most Recent Fault Record
06-21
Sixth Most Recent Fault Record
Control
mode
VF VFPG FOCPM
Factory setting: 0
Readings 0 No fault
1 Over-current during acceleration (ocA)
2 Over-current during deceleration (ocd)
3 Over-current during constant speed (ocn)
4 Ground fault (GFF)
5 Reserved
6 Over-current at stop (ocS)
7 Over-voltage during acceleration (ovA)
8 Over-voltage during deceleration (ovd)
9 Over-voltage during constant speed (ovn)
10 Over-voltage at stop (ovS)
11 Low-voltage during acceleration (LvA)
12 Low-voltage during deceleration (Lvd)
13 Low-voltage during constant speed (Lvn)
14 Low-voltage at stop (LvS)
15 Phase loss (PHL)
16 IGBT heat sink over-heat (oH1)
17 heat sink over-heat 40HP above (oH2)
18 TH1 open loop error (tH1o)
19 Reserved
20 Reserved
21 Over-load (oL) (150% 1Min)
22 Motor over-load (EoL1)
23 Reserved
24 Reserved
25 Reserved
26 Over-torque 1 (ot1)
27 Over-torque 1 (ot2)