Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-7
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
01.18 Accel Time 4 0.00~600.00 sec 3.00
01.19 Decel Time 4 0.00~600.00 sec 2.00
01.20 Reserved
01.21 Reserved
01.22 Reserved
01.23 Switch Frequency
between 1st/4th
Accel/decel
0~4000rpm (0~400.00Hz) 0 (0.00)
01.24 S-curve for
Acceleration
Departure Time S1
0.0~25.0 sec 0.0
01.25 S-curve for
Acceleration Arrival
Time S2
0.0~25.0 sec 0.0
01.26 S-curve for
Deceleration
Departure Time S3
0.0~25.0 sec 0.0
01.27 S-curve for
Deceleration Arrival
Time S4
0.0~25.0 sec 0.0
01.28 Mode Selection when
Frequency < Fmin
0Output waiting
1Zero-speed operation
2 Fmin (4
th
output frequency
setting)
0
01.29 Switch Frequency
form S to S5
0~4000rpm (0~400.00Hz) 0 (0.00)
01.30 S-curve for
Deceleration Arrival
Time S5
0.0~25.0 sec 0.0
01.31 Time required for
deceleration to stop
0.00~600.00 sec 2.00
NOTE: With Delta ECMD-E9 Series motor, rated frequency is 2000rpm and maximum frequency is
3000rmp.