Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-23
Group 09 Communication Parameters : The parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
09.00 Communication
Address
1~254 1
09.01 Transmission Speed
(Keypad)
4.8~38.4Kbps 9.6
09.02 Transmission Fault
Treatment (Keypad)
0: Warn and keep operation
1: Warn and ramp to stop
2: Reserved
3: No action and no display
3
09.03 Time-out Detection
(Keypad)
0.0100.0 sec 0.0
09.04 Communication
Protocol (Keypad)
0: 7N1 (ASCII)
1: 7N2 (ASCII)
2: 7E1 (ASCII)
3: 7O1 (ASCII)
4: 7E2 (ASCII)
5: 7O2 (ASCII)
6: 8N1 (ASCII)
7: 8N2 (ASCII)
8: 8E1 (ASCII)
9: 8O1 (ASCII)
10: 8E2 (ASCII)
11: 8O2 (ASCII)
12: 8N1 (RTU)
13: 8N2 (RTU)
14: 8E1 (RTU)
15: 8O1 (RTU)
16: 8E2 (RTU)
17: 8O2 (RTU)
1
09.05 Response Delay
Time
0.0~200.0ms 2.0