Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-18
Revision May 2009, 00DE, V0.50
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
Recent Fault
Record
(ocA)
06.18 Third Most Recent
Fault Record
2: Over-current during deceleration
(ocd)
0 ○ ○ ○
06.19 Fourth Most Recent
Fault Record
3: Over-current during constant
speed (ocn)
0 ○ ○ ○
06.20 Fifth Most Recent
Fault Record
4: Ground fault (GFF)
0 ○ ○ ○
06.21 Sixth Most Recent
Fault Record
5:Reserved
6: Over-current at stop (ocS)
7: Over-voltage during acceleration
(ovA)
8: Over-voltage during deceleration
(ovd)
9: Over-voltage during constant
speed (ovn)
10: Over-voltage at stop (ovS)
11: Low-voltage during acceleration
(LvA)
12: Low-voltage during deceleration
(Lvd)
13: Low-voltage during constant
speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss protection (PHL)
16: IGBT heat sink over-heat (oH1)
17:Reserved
18:18: TH1 open loop error (tH1o)
19~20:Reserved
21: over-load (oL) (150% 1Min)
22: Motor over-load (EoL1)
23~25:Reserved
26: over-torque 1 (ot1)
27: over-torque 1 (ot2)
28: Reserved
0 ○ ○ ○