Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-48
Revision May 2009, 00DE, V0.50
Group 2 Digital Input/Output Parameters This parameter can be set during operation.
02-00
2-wire/3-wire Operation Control
Control
mode
VF VFPG FOCPM
Factory setting: 0
Settings 0 FWD/STOP, REV/STOP
1 FWD/STOP, REV/STOP (Line Start Lockout)
2 RUN/STOP, REV/FWD
3 RUN/STOP, REV/FWD (Line Start Lockout)
4 3-wire
5 3-wire (Line Start Lockout)
Three of the six methods include a “Line Start Lockout” feature. When line start lockout is
enabled, the drive will not run once applying the power. The Line Start Lockout feature
doesn’t guarantee the motor will never start under this condition. It is possible the motor may
be set in motion by a malfunctioning switch.
This parameter is used to control operation from external terminals. There are three different
control modes.
02-00 Control Circuits of the External Terminal
0, 1
2-wire operation control (1)
FWD/STOP
REV/STOP
2, 3
2-wire operation control (2)
RUN/STOP
REV/FWD
4, 5
3-wire operation control