Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-8
Revision May 2009, 00DE, V0.50
Group 02 Digital : The parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
02.00 2-wire/3-wire
Operation Control
02-wire operation mode1,
FWD/STOP, REV/STOP
12 –wire mode1, FWD/STOP,
REV/STOP (Line Start Lockout)
22-wire mode2, RUN/STOP,
REV/FWD
32-wire mode2, RUN/STOP,
REV/FWD (Line Start Lockout)
43-wire,
53-wire (Line Start Lockout).
0
02.01 Multi-Function
Command Input
(MI3)
0no function 1
02.02 Multi-Function
Input (MI4)
1Multi-step command 1 2
02.03 Multi-Function
Command Input
(MI5)
2Multi-step command 2 3
3Multi-step command 3 4
4Multi-step command 4
5Reset
6Reserved
7acceleration/deceleration speed
inhibit
8the 1st, 2nd
acceleration/deceleration time
selection
9the 3rd, 4th
acceleration/deceleration time
selection
10: EF input (Pr.07-28)
11: Reserved
02.04 Multi-Function
Command Input
(MI6)
12: Stop output