Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-8
Revision May 2009, 00DE, V0.50
Group 02 Digital : The parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
02.00 2-wire/3-wire
Operation Control
0:2-wire operation mode1,
FWD/STOP, REV/STOP
1:2 –wire mode1, FWD/STOP,
REV/STOP (Line Start Lockout)
2:2-wire mode2, RUN/STOP,
REV/FWD
3:2-wire mode2, RUN/STOP,
REV/FWD (Line Start Lockout)
4:3-wire,
5:3-wire (Line Start Lockout).
0 ○ ○ ○
02.01 Multi-Function
Command Input
(MI3)
0:no function 1 ○ ○ ○
02.02 Multi-Function
Input (MI4)
1:Multi-step command 1 2 ○ ○ ○
02.03 Multi-Function
Command Input
(MI5)
2:Multi-step command 2 3 ○ ○ ○
3:Multi-step command 3 4 ○ ○ ○
4:Multi-step command 4 ○ ○ ○
5:Reset ○ ○ ○
6:Reserved ○ ○ ○
7:acceleration/deceleration speed
inhibit
○ ○ ○
8:the 1st, 2nd
acceleration/deceleration time
selection
○ ○ ○
9:the 3rd, 4th
acceleration/deceleration time
selection
○ ○ ○
10: EF input (Pr.07-28) ○ ○ ○
11: Reserved ○ ○ ○
02.04 Multi-Function
Command Input
(MI6)
12: Stop output ○ ○ ○