Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-79
It is used to set the rated speed of the motor and need to set according to the value indicated
on the motor nameplate.
08-04
Number of Motor Poles
Control
mode
FOCPM
Factory setting: 4
Settings 2 to 96
It is used to set the number of motor poles (must be an even number).
08-05
Rs of Motor
Control
mode
FOCPM
Factory setting: #
Settings
0.000~65.535Ω
08-06
Ld of Motor
Control
mode
FOCPM
Factory setting: #
08-07
Lq of Motor
Control
mode
FOCPM
Factory setting: #
Settings 0.0~6553.5mH
08-08
Back Electromotive Force
Control
mode
FOCPM
Factory setting: #
Settings 0.0~6553.5Vrms
This parameter is used to set back electromotive force (phase-phase RMS value) when the
motor is operated in the rated speed.
It can get RMS value by Pr.08-00=2 (Motor Auto Tuning).
08-09
Angle between Magnetic Pole and PG Origin
Control
mode
FOCPM
Factory setting: 360.0
Settings
0.0~360.0°
This function is used to measure the angle between magnetic pole and PG origin.