General Specifications
Operation Functions
Built-in AVR, over-voltage/over-current stall prevention, 5 fault records,
reverse inhibition, momentary power loss restart, auto torque compensation,
adjustable carrier frequency, output speed limits, parameter reset, PID
control, external counter, MODBUS communication, abnormal reset,
abnormal re-start and NPN/PNP selection
Display Keypad
6-key, 7-segment LED with 4-digit, 5 status LEDs, setting speed, display
actual output speed, output current, custom units, parameter values for setup
and lock, faults, RUN, STOP, RESET, FWD/REV
Built-in EMI Filter For 230V 1-phase and 460V 3-phase models.
Enclosure Rating IP20
Pollution Degree 2
Installation Location Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Ambient Temperature
-10
o
C to 50
o
C (40
o
C for side-by-side mounting) Non-Condensing and not
frozen
Storage Temperature -20
o
C to 60
o
C
Ambient Humidity Below 90% RH (non-condensing)
Environmental Conditions
Vibration 9.80665m/s
2
(1G) less than 20Hz, 5.88m/s