Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 6 Fault Code Information and Maintenance| BLD-E1 Series
Revision May 2009, 00DE, V0.50 6-3
Fault
Name
Fault Descriptions
Corrective Actions
DC BUS over-voltage during
acceleration
(230V: DC 405V; 460V: DC
810V)
1. Check if the input voltage falls within the rated
brushless DC motor drive input voltage range.
2. Check for possible voltage transients.
3. If DC BUS over-voltage due to regenerative
voltage, please increase the Deceleration
Time or add an optional brake resistor
DC BUS over-voltage during
deceleration
230V: DC 405V; 460V: DC
810V
1. Check if the input voltage falls within the rated
brushless DC motor drive input voltage range.
2. Check for possible voltage transients.
3. If DC BUS over-voltage due to regenerative
voltage, please increase the Deceleration
Time or add an optional brake resistor
DC BUS over-voltage during
constant speed
230V: DC 405V; 460V: DC
810V
1. Check if the input voltage falls within the rated
brushless DC motor drive input voltage range.
2. Check for possible voltage transients.
3. If DC BUS over-voltage due to regenerative
voltage, please increase the Deceleration
Time or add an optional brake resistor
DC BUS over-voltage at stop
1. Check if the input voltage falls within the rated
brushless DC motor drive input voltage range.
2. Check for possible voltage transients.
DC BUS voltage is less than
Pr.06-00 during acceleration.
1. Check if the input voltage is normal
2. Check for possible sudden load
DC BUS voltage is less than
Pr.06-00 during deceleration
1. Check if the input voltage is normal
2. Check for possible sudden load
DC BUS voltage is less than
Pr.06-00 during constant
speed.
1. Check if the input voltage is normal
2. Check for possible sudden load
Low voltage at stop
1. Check if the input voltage is normal
2. Check for possible sudden load
Phase loss
Check Power Source Input if all 3 input phases are
connected without loose contacts.