Revision May 2009, 00DE, V0.50 3-1
Chapter 3 Keypad and Start Up
3.1 Keypad
3.2 Operation Method
3.3 Trial Run
Make sure that the wiring is correct. In particular, check that the
output terminals U/T1, V/T2, W/T3 are NOT connected to power
and that the drive is well grounded.
Verify that no other equipment is connected to the motor.
Do NOT operate the brushless DC motor drive with humid hands.
Check if it displays 2000.0 on the digital keypad after power is
applied.
It should be stopped when fault occurs during running and refer to
“Fault Code Information and Maintenance” for solution. Please do
NOT touch output terminals U, V, W when power is still applied to
L1/R, L2/S, L3/T even when the brushless DC motor drive has
stopped. It may cause electric shock if touching the output
terminals U, V, W.