Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-26
Revision May 2009, 00DE, V0.50
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
Width Adjustment
10.21 ASR1/ASR2 Width
Adjustment
0~4000RPM (0.00~400.0Hz) 5.00 ○ ○
10.22 Operation Time of
Zero Speed
0.000~65.535 sec 0.250 ○
10.23 Filter Time of Zero
Speed
0.000~65.535 sec 0.004 ○