Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-25
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
10.09 Encoder Stall and Slip
Error Treatment
0: Warn and keep operation
1: Warn and decelerate to stop
2: Warn and stop operation
2
10.10 Mode Selection for
UVW Input
0: Z signal is at the falling edge
of U-phase
1: Z signal is at the rising edge o
f
U-phase
0
10.11 ASR (Auto Speed
Regulation) Control
(P) of Zero Speed
0.0~500.0% 100.0
10.12 ASR (Auto Speed
Regulation) Control (I)
of Zero Speed
0.000~10.000 sec 0.200
10.13 ASR (Auto Speed
Regulation) Control
(P) 1
0.0~500.0% 100.0
10.14 ASR (Auto Speed
Regulation) Control (I)
1
0.000~10.000 sec 0.200
10.15 ASR (Auto Speed
Regulation) Control
(P) 2
0.0~500.0% 100.0
10.16 ASR (Auto Speed
Regulation) Control (I)
2
0.000~10.000 sec 0.200
10.17 ASR 1/ASR2 Switch
Frequency
0~4000RPM (0.00~400.0Hz) 7.00
10.18 ASR Primary Low
Pass Filter Gain
0.000~0.350 sec 0.008
10.19 Zero Speed Gain (P) 0~655.00% 80.00
10.20 Zero Speed/ASR1 0~4000RPM (0.00~400.0Hz) 5.00