Delta BLD-E1 Series Outboard Motor User Manual


 
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-6
Revision May 2009, 00DE, V0.50
Group 01 Basic Parameters : The parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
01.00 Maximum Operation
Frequency
120~4000RPM (10~400Hz) 3000
(250)
01.01 1st Output
Frequency Setting 1
Base Frequency/
Rated Motor
Frequency
0~400.00Hz 60.00
01.02 1st Output Voltage
Setting 1
(Base Voltage/ Rated
Motor Voltage
230V Series0.0V~255.0V
460V Series0.0V~510.0V
220.0
440.0
01.03 2nd Output
Frequency Setting 1
0~400.00Hz 0.50
01.04 2nd Output Voltage
Setting 1
230V Series0.0V~255.0V
460V Series0.0V~510.0V
5.0
10.0
01.05 3rd Output
Frequency Setting 1
0~400.00Hz 0.50
01.06 3rd Output Voltage
Setting 1
230V Series0.0V~255.0V
460V Series0.0V~510.0V
5.0
10.0
01.07 4th Output
Frequency Setting 1
0~400.00Hz 0.00
01.08 4th Output Voltage
Setting 1
230V Series0.0V~255.0V
460V Series0.0V~510.0V
0.0
0.0
01.09 Start Frequency 0~4000rpm (0~400.00Hz) 6 (0.5)
01.10 Output Frequency
Upper Limit
0~4000rpm (0~400.00Hz) 3000
(250)
01.11 Output Frequency
Lower Limit
0~4000rpm (0~400.00Hz) 0 (0.00)
01.12 Accel Time 1 0.00~600.00 sec 3.00
01.13 Decel Time 1 0.00~600.00 sec 2.00
01.14 Accel Time 2 0.00~600.00 sec 3.00
01.15 Decel Time 2 0.00~600.00 sec 2.00
01.16 Accel Time 3 0.00~600.00 sec 3.00
01.17 Decel Time 3 0.00~600.00 sec 2.00