Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-52
Revision May 2009, 00DE, V0.50
Settings Functions Descriptions
27 ASR1/ASR2 selection
ON: speed will be adjusted by ASR 2 setting.
OFF: speed will be adjusted by ASR 1 setting.
28
Emergency stop (EF1)
(Motor coasts to stop)
When it is ON, the drive will execute emergency stop
with fault code 50 (EF1)
29-30 Reserved
31 High torque bias
32 Middle torque bias
33 Low torque bias
When Pr.07-19 is set to 3:
31: The high torque bias is according to the Pr.07-21
setting.
32: The middle torque bias is according to the Pr.07-22
setting.
33: The low torque bias is according to the Pr.07-23
setting.
31 32 33 Torque Bias
OFF OFF OFF No
OFF OFF ON 07-23
OFF ON OFF 07-22
OFF ON ON 07-23+07-22
ON OFF OFF 07-21
ON OFF ON 07-21+07-23
ON ON OFF 07-21+07-22
ON ON ON 07-21+07-22+07-23
34-37 Reserved
38
Disable write EEPROM
function
When this function is enabled, you can’t write into
EEPROM.
39 Reserved
40 Enable drive function
When this function is enabled, the drive function can be
executed. This function can be used with multi-function
output (setting Pr.02-11~Pr.02-14 to 15) and (Pr.02-31
and Pr.02-32).
02-05
Reserved
02-06
Reserved
02-07
Reserved
02-08
Reserved