Polycom, Inc. 22
System Configuration
This section explains the functions used for system administration in detail.
Check System Status on Home
You can find real time system status and information on Home.
Signaling Connection
Shows connection information and recording status of the calls to and from video endpoint or MCUs with
this Capture Server. Click to expand detailed parameters information. The table below provides
parameters descriptions.
Signal Connection Parameters
You can control the recording using the controls:
● : Start recording.
● : Pause recording.
● : Resume recording.
● : Stop recording.
● : End the connection.
You can dial out to connect the endpoint to record using Dial out to record.
Parameter Description
Far End Number The far end number used by the connection.
Start Time When the calls started.
Signaling Type H.323 or SIP.
Dial In/Out Whether the connection is incoming or outgoing.
VRR Number The VRR number used by the connection.
Live Streaming Whether the connection is performing live streaming.
Detail Additional information like VRR name, audio type, audio call rate, video type,
video call rate, etc.
Real Time Information Displays call address, audio packet loss, video resolution, video frame rate,
etc.