Dell 7.4 Life Jacket User Manual


 
Cause and
Action
Cause: The only physical disk available to be assigned as a hot spare is using SAS
technology. The physical disks in the virtual disk are using SATA technology.
Because of this difference in technology, the hot spare cannot rebuild data if one
of the physical disks in the virtual disk fails.
Action: Add a SATA disk that is large enough to be used as the hot spare and assign
the new disk as a hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2210
Description Battery requires reconditioning. Initiate the battery learn cycle.
Severity Warning / Non-critical
Cause and
Action
Cause: Battery is in warn only mode and requires reconditioning.
Action: Initiate the battery learn cycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1153
Event ID — 2211
Description The physical disk is not supported.
Severity Warning / Non-critical
Cause and
Action
Cause: The physical disk may not have a supported version of the firmware or the
disk may not be supported by your service provider.
Action: If the disk is supported, update the firmware to a supported version. If the
disk is not supported by your service provider, replace the disk with one that is
supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
111