Dell 7.4 Life Jacket User Manual


 
SNMP Trap
Numbers
751
Event ID — 2399
Description The Physical Disk Power status changed from 1% to 2%.
Severity OK / Normal / Informational
Cause and
Action
Cause: The physical disk power status is changed from one state to another. A
physical disk can have the following power statuses: spun down, transition, and
spun up.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2400
Description Physical disk configuration data updated as it was stale.
Severity Informational
Cause and
Action
Cause: The physical disk configuration data is updated because it was outdated.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2401
Description Configuration command could not be committed to disk. Configuration has to be
re applied.
Severity Failure / Error
Cause and
Action
Cause: The virtual disk configuration command did not succeed.
Action: Check for the recent configuration that has not taken effect. Re-apply the
configuration.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
175