Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2110
Description SMART warning degraded.
Severity Warning / Non-critical
Cause and
Action
Cause: A disk is degraded and has received a SMART alert (predictive failure). The
disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a
member of a nonredundant virtual disk, then back up the data before replacing the
disk.
CAUTION: Removing a physical disk that is included in a non-redundant
virtual disk causes the virtual disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2111
Description Failure prediction threshold exceeded due to test.
Severity Warning / Non-critical
Cause and
Action
Cause: A disk has received a SMART alert (predictive failure) due to test conditions.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2112
Description Enclosure was shut down.
Severity Critical / Failure / Error
77