Dell 7.4 Life Jacket User Manual


 
Severity Warning / Non-critical
Cause and
Action
Cause: The version of the kernel and the driver do not meet the minimum
requirements. Storage Management may not be able to display the storage or
perform storage management functions until you have updated the system to
meet the minimum requirements.
Action: See the Readme file for a list of validated kernel and driver versions. Update
the system to meet the minimum requirements and then reinstall Storage
Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2168
Description The non-RAID SCSI driver version is older than the minimum required level. See
readme.txt for the validated driver version.
Severity Warning / Non-critical
Cause and
Action
Cause: The version of the driver does not meet the minimum requirements.
Storage Management may not be able to display the storage or perform storage
management functions until you have updated the system to meet the minimum
requirements.
Action: See the Readme file for the validated driver version. Update the system to
meet the minimum requirements and then reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2169
Description The controller battery needs to be replaced.
Severity Critical / Failure / Error
Cause and
Action
Cause: The controller battery cannot be recharged. The battery may be old or it
may have been already recharged the maximum number of times. In addition, the
battery charger may not be working.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2118
Local Response Agent (LRA) Number: 2101
97