Dell 7.4 Life Jacket User Manual


 
Cause and
Action
Hardware RAID: Cause and Action
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
Perform a backup with the Verify option.
If the file backup fails, try to restore the failed file from a previous backup.
When the backup with the Verify option is complete without any errors, delete
the Virtual Disk.
Recreate a new Virtual Disk with new drives.
Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2348
Description The rebuild failed due to errors on the target physical disk.
Severity Critical / Failure / Error
Cause and
Action
Cause:You are attempting to rebuild data on a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after
replacing the disk, initiate the Rebuild task. You may need to assign the new disk as
a hot spare to initiate the rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2349
Description A bad disk block could not be reassigned during a write operation.
Severity Critical / Failure / Error
Cause and
Action
Cause: A write operation could not complete because the disk contains bad disk
blocks that could not be reassigned. Data loss may have occurred and data
redundancy may also be lost.
Action: Replace the disk.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2346
158