Dell 7.4 Life Jacket User Manual


 
Event Id — 2313
Description A power supply in the enclosure has a DC failure.
Severity Warning / Non-critical
Cause and
Action
Cause: The power supply has a DC failure.
Action: Replace the power supply.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: 2122, 2333
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1003
Event ID — 2314
Description The initialization sequence of SAS components failed during system startup. SAS
management and monitoring is not possible.
Severity Critical / Failure / Error
Cause and
Action
Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported
versions of the drivers and firmware. Also, you may need to reinstall Storage
Management or Server Administrator because of some missing installation
components.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2051
SNMP Trap
Numbers
104
Event Id — 2315
Description Diagnostic message %1
Severity OK / Normal / Informational
Cause and
Action
Cause: The %1 indicates a substitution variable. The text for this substitution
variable is generated by the utility that ran the diagnostics and is displayed with the
alert in the alert log. This text can vary depending on the situation. This alert is for
informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
146