System Event Log Messages for IPMI
Systems
The tables in this chapter list the system event log (SEL) messages, their severity, and cause.
NOTE: For corrective actions, see the appropriate documentation.
Temperature Sensor Events
The temperature sensor event messages help protect critical components by alerting the systems
management console when the temperature rises inside the chassis. These event messages use
additional variables, such as sensor location, chassis location, previous state, and temperature sensor
value or state.
Table 5. Temperature Sensor Events
Event Message Severity Cause
<Sensor Name/Location>
temperature sensor detected a
failure <Reading> where <Sensor
Name/Location> is the entity
that this sensor is monitoring.
For example, "PROC Temp" or
"Planar Temp." Reading is
specified in degree Celsius. For
example 100 C.
Critical Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> exceeded
the critical threshold.
<Sensor Name/Location>
temperature sensor detected a
warning <Reading>.
Warning Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> exceeded
the non-critical threshold.
<Sensor Name/Location>
temperature sensor returned to
warning state <Reading>.
Warning Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> returned
from critical state to non-critical state.
<Sensor Name/Location> temperature
sensor returned to normal state <Reading>.
Information Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> returned
to normal operating range.
The <Sensor Name/ Location>
temperature is less than the lower warning
threshold.
Warning Temperature of the backplane, system
board, system inlet, or the carrier in the
specified system <Sensor Name/Location>
entered into non-critical state.