Previous state was: <State>
Processor sensor status: <status>
Severity Warning
Cause A processor sensor in the specified system is in a throttled state. The sensor
location, chassis location, previous state and processor sensor status information is
provided.
Event ID — 1604
Description
Processor sensor detected a failure value Sensor Location:
<Location in chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Processor sensor status: <status>
Severity Error
Cause A processor sensor in the specified system is disabled, has a configuration error, or
experienced a thermal trip. The sensor location, chassis location, previous state and
processor sensor status are provided.
Pluggable Device Messages
The pluggable device messages listed provides status and error information when some devices, such as
memory cards, are added or removed.
Event ID — 1650
Description
Device plug event type unknown Device location: <Location in
chassis, if available>
Chassis Location: <Name of chassis, if available>
Additional details: <Additional details for the events, if
available>
Severity Information
Cause A pluggable device event message of unknown type was received. The device
location, chassis location, and additional event details, if available, are provided.
Event ID — 1651
Description
Device added to system Device location: <Location in chassis>
Chassis Location: <Name of chassis>
Additional details: <Additional details for the events>
Severity Information
48