Event ID — 2165
Description The RAID controller firmware and driver validation was not performed. The
configuration file cannot be opened.
Severity Warning / Non-critical
Cause and
Action
Cause: Storage Management is unable to determine whether the system has the
minimum required versions of the RAID controller firmware and drivers. This
situation may occur for a variety of reasons. For example, the installation directory
path to the configuration file may not be correct. The configuration file may also
have been removed or renamed.
Action: Reinstall Storage Management
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2166
Description The RAID controller firmware and driver validation was not performed. The
configuration file is out of date, missing the required information, or not properly
formatted to complete the comparison.
Severity Warning / Non-critical
Cause and
Action
Cause: Storage Management is unable to determine whether the system has the
minimum required versions of the RAID controller firmware and drivers. This
situation has occurred because a configuration file is out of date, missing the
required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2167
Description The current kernel version and the non-RAID SCSI driver version are older than the
minimum required levels. See readme.txt for a list of validated kernel and driver
versions.
96