Dell 7.4 Life Jacket User Manual


 
Event ID — 2366
Description Dedicated spare imported as global due to missing arrays.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2367
Description Rebuild is not possible because mixing of different media type (SSD/HDD) and bus
protocols (SATA/SAS) is not supported on the same virtual disk.
Severity Warning / Non-critical
Cause and
Action
Cause: The physical disk is using an incompatible technology.
Action: All physical disks in the virtual disk must use the same technology. You
cannot use both SAS and SATA physical disks in the same virtual disk. Remove the
physical disk and insert a new physical disk that uses the correct technology. If the
rebuild does not start automatically after you have inserted a suitable physical disk,
then run the Rebuild task.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2368
Description The SCSI Enclosure Processor (SEP) has been rebooted as part of the firmware
download operation and is unavailable until the operation completes.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2049, 2052, 2162, 2292
Local Response Agent (LRA) Number: None
164