Event ID — 1007
Description
User initiated host system control action Action requested was:
<Action>
Severity Information
Cause User requested a host system control action to reboot, power off, or power cycle
the system. Alternatively, the user had indicated protective measures to be initiated
in the event of a thermal shutdown.
Event ID — 1008
Description
Systems Management Data Manager Started
Severity Information
Cause Systems Management Data Manager services were started.
Event ID — 1009
Description
Systems Management Data Manager Stopped
Severity Information
Cause Systems Management Data Manager services were stopped.
Event ID — 1011
Description
RCI table is corrupt
Severity Error
Cause This message is generated when the BIOS Remote Configuration Interface (RCI)
table is corrupted or cannot be read by the systems management software.
Event ID — 1012
Description
IPMI Status Interface: <the IPMI interface being used>,
<additional information if available and applicable >
Severity Information
Cause
This message is generated to indicate the Intelligent Platform Management
Interface (IPMI) status of the system.
Additional information, when available, includes Baseboard Management
Controller (BMC) not present, BMC not responding, System Event Log (SEL) not
present, and SEL Data Record (SDR) not present.