Dell 7.4 Life Jacket User Manual


 
Event ID — 2139
Description Enclosure alarm disabled.
Severity OK / Normal / Informational
Cause and
Action
Cause: A user has disabled the enclosure alarm.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2140
Description Dead disk segments restored.
Severity OK / Normal / Informational
Cause and
Action
Cause: Disk space that was formerly “dead” or inaccessible to a redundant virtual
disk has been restored. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2141
Description Physical disk dead segments removed.
Severity OK / Normal / Informational
Cause and
Action
Cause: Portions of the physical disk were formerly inaccessible. The disk space
from these dead segments has been recovered and is now usable. Any data
residing on these dead segments has been lost. This alert is for informational
purposes.
Action: Check for factors that may cause overheating. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and
examine whether the enclosure is located near a heat source. Make sure the
enclosure has enough ventilation and that the room temperature is not too hot.
See the physical disk enclosure documentation for more diagnostic information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
87