Dell 7.4 Life Jacket User Manual


 
Event Message Severity Cause
PS 1 Status: Power supply
sensor for PS 1,
configuration error was
asserted.
Warning/Critical This event is generated when an
invalid power supply
configuration is detected.
PS 1 Status: Power supply
sensor for PS 1,
configuration error was
deasserted.
Information This event is generated when the
power supply has recovered
from an earlier invalid
configuration.
Power supply <number> is
present.
Information This event is generated when the
power supply is plugged in.
Power supply <number> is
absent.
Critical This event is generated when the
power supply is removed.
Power supply <number>
failed.
Critical This event is generated when the
power supply has failed.
A predictive failure
detected on power supply
<number>.
Warning This event is generated when the
power supply is about to fail.
The power input for power
supply <number> is lost.
Critical This event is generated when
input power is removed from the
power supply.
The input power for power
supply <number> has been
restored.
Information This event is generated if the
power supply has been
reconnected or replaced.
Power supply <number> is
incorrectly configured.
Critical/Warning This event is generated when an
invalid power supply
configuration is detected.
Power supply <number> is
correctly configured.
Information This event is generated when the
power supply has recovered
from an earlier invalid
configuration.
Power supply <number> is
operating normally.
Information This event is generated when the
power supply has recovered
from an earlier failure event.
Cannot communicate with
power supply <number>.
Critical The power supply may operate,
however power supply
monitoring is degraded.
The temperature for power
supply <number> is in a
warning range.
Warning Temperature of specified power
supply entered into non-critical
state.
209