Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2080
Description Physical disk initialization failed.
Severity Critical / Failure / Error
Cause and
Action
Cause: The physical disk has failed or is not functioning.
Action: Replace the failed or non-functional disk. You can identify a disk that has
failed by locating the disk that has a red “X” for its status. Restart the initialization.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2081
Description Virtual disk reconfiguration failed.
Severity Critical / Failure / Error
Cause and
Action
Hardware RAID:
Cause: A physical disk included in the virtual disk has failed or is not functioning. A
user may also have cancelled the reconfiguration.
Action: Replace the failed or non-functional disk. You can identify a disk that has
failed by locating the disk that displays a red X in the status field.
If the physical disk is part of a redundant array, then rebuild the physical disk. When
finished, restart the reconfiguration.
Software RAID:
• Perform a backup with the Verify option.
• If the file backup fails, try to restore the failed file from a previous backup.
• When the backup with the Verify option is complete without any errors, delete
the Virtual Disk.
• Recreate a new Virtual Disk with new drives.
• Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
67