SNMP Trap
Numbers
901
Event ID — 2353
Description The enclosure temperature has returned to normal.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2353 is a clear alert for alerts 2100 and 2101.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1051
Event ID — 2354
Description Enclosure firmware download in progress.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is provided for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2355
Description Enclosure firmware download failed.
Severity Warning / Non-critical
Cause and
Action
Cause: The system was unable to download firmware to the enclosure. The
controller may have lost communication with the enclosure. There may have been
problems with the data transfer or the download media may be corrupt.
Action: Attempt to download the enclosure firmware again. If problems continue,
verify that the controller can communicate with the enclosure. Make sure that the
enclosure is powered on. Check the cables. See the Cables Attached Correctly
section for more information on checking the cables. Verify the health of the
enclosure and its components. To verify the health of the enclosure, select the
enclosure object in the tree view. The Health subtab displays a red X or yellow
exclamation point for enclosure components that are failed or degraded.
160