Dell 7.4 Life Jacket User Manual


 
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2127
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2282
Description Hot spare SMART polling failed.
Severity Critical / Failure / Error
Cause and
Action
Cause: The controller firmware attempted a SMART polling on the hot spare but
was unable to complete it. The controller has lost communication with the hot
spare.
Action: Check the health of the disk assigned as a hot spare. You may need to
replace the disk and reassign the hot spare. Make sure the cables are attached
securely. See the Server Administrator Storage Management User’s Guide, for more
information on checking the cables.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2283
Description A redundant path is broken.
Severity Warning / Non-critical
Cause and
Action
Cause: The controller has two connectors that are connected to the same
enclosure. The communication path on one connector has lost connection with
the enclosure. The communication path on the other connector is reporting this
loss.
Action: Make sure the cables are attached securely and both enclosure
management modules (EMMs) are healthy. See the Cables Attached Correctly
section for more information on checking the cables.
Related Alert
Information
Clear Alert Number: 2284
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
135