Dell 7.4 Life Jacket User Manual


 
SNMP Trap
Numbers
1203
Event ID — 2345
Description The virtual disk initialization failed.
Severity Critical / Failure / Error
Cause and
Action
Cause: The controller cannot communicate with attached devices. A disk may be
removed or contain errors. Cables may also be loose or defective.
Action: Verify the health of attached devices. Review the Alert Log for significant
events. Make sure the cables are attached securely. See the Cables Attached
Correctly section for more information on checking the cables.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2346
Description Error occurred: %1.
Severity Warning / Non-critical
Cause and
Action
Cause: A physical device may have an error. The %1 indicates a substitution
variable. The text for this substitution variable is generated by the firmware and is
displayed with the alert in the alert log. This text can vary depending on the
situation.
Action: Verify the health of attached devices. Review the alert log for significant
events. Run the PHY integrity diagnostic tests. You may need to replace faulty
hardware. Make sure that the cables are attached securely. See the hardware
documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095,
2129, 2201, 2203, 2270, 2282, 2369
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2347
Description The rebuild failed due to errors on the source physical disk.
Severity Critical / Failure / Error