Event ID — 2396
Description The Check Consistency detected uncorrectable multiple medium errors.
Severity Critical / Failure / Error
Cause and
Action
Cause: The Check Consistency task detects uncorrectable multiple errors.
Action: Replace the failed physical disk. You can identify the failed disk by locating
the disk that has a red “X” for its status. Rebuild the physical disk. When finished,
restart the check consistency operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1204
Event ID — 2397
Description The Check Consistency completed with uncorrectable errors.
Severity Critical / Failure / Error
Cause and
Action
Cause: The Check Consistency task detected uncorrectable multiple errors.
Action: Replace the failed physical disk. You can identify the failed disk by locating
the disk that has a red “X” for its status. Rebuild the physical disk. When finished,
restart the check consistency operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1204
Event ID — 2398
Description The Manage Physical Disk Power property(s) changed.
Severity OK / Normal / Informational
Cause and
Action
Cause: The Manage Physical Disk Power properties are changed.
Action: None.