Dell 7.4 Life Jacket User Manual


 
SNMP Trap
Numbers
904
Event ID — 2108
Description SMART warning.
Severity Warning / Non-critical
Cause and
Action
Cause: A disk has received a SMART alert (predictive failure). The disk is likely to fail
in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a
member of a non-redundant virtual disk, then back up the data before replacing
the disk.
CAUTION: Removing a physical disk that is included in a non-redundant
virtual disk causes the virtual disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2109
Description SMART warning temperature.
Severity Warning / Non-critical
Cause and
Action
Cause: A disk has reached an unacceptable temperature and received a SMART
alert (predictive failure). The disk is likely to fail in the near future.
Action 1: Determine why the physical disk has reached an unacceptable
temperature. A variety of factors can cause the excessive temperature. For
example, a fan may have failed, the thermostat may be set too high, or the room
temperature may be too hot or cold. Verify that the fans in the server or enclosure
are working. If the physical disk is in an enclosure, you should check the
thermostat settings and examine whether the enclosure is located near a heat
source.
Make sure the enclosure has enough ventilation and that the room temperature is
not too hot. See the physical disk enclosure documentation for more diagnostic
information.
Action 2 : If you cannot identify why the disk has reached an unacceptable
temperature, then replace the disk. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant
virtual disk causes the virtual disk to fail and may cause data loss.
76