Dell 7.4 Life Jacket User Manual


 
Event ID — 2930
Description Even though caching was enabled in write-back mode, it is currently operating in
write-through mode.: FluidCache.
Severity Warning
Cause and
Action
To resolve the issue, add a PCIe SSD to the cache pool.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1203, 1503
Event ID — 2931
Description Even though caching was enabled in write-back or write-through mode, it is
currently operating in pass-through mode.: FluidCache.
Severity Warning
Cause and
Action
To resolve the issue, add one or more PCIe SSDs to the cache pool.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1603
Event ID — 2932
Description Caching is no longer degraded to write-through mode and is now operating in
write-back mode.: FluidCache.
Severity Warning
Cause and
Action
No action required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1203, 1503
198