Dell 7.4 Life Jacket User Manual


 
SNMP Trap
Numbers
751
Event ID — 2316
Description Diagnostic message %1
Severity Critical / Failure / Error
Cause and
Action
Cause: A diagnostics test failed. The %1 indicates a substitution variable. The text
for this substitution variable is generated by the utility that ran the diagnostics and
is displayed with the alert in the alert log. This text can vary depending on the
situation.
Action: See the documentation for the utility that ran the diagnostics for more
information
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2318
Description Problems with the battery or the battery charger have been detected. The battery
health is poor.
Severity Warning / Non-critical
Cause and
Action
Cause: The battery or the battery charger is not functioning properly.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2188
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2319
Description Single-bit ECC error. The DIMM is degrading.
Severity Warning / Non-critical
Cause and
Action
Cause: The DIMM is beginning to malfunction.
Action: Replace the DIMM to avoid data loss or data corruption. The DIMM is a part
of the controller battery pack. See your hardware documentation for information
on replacing the DIMM or contact technical support.