Severity OK / Normal / Informational
Cause and
Action
Cause: A SCSI device experienced an error, but may have recovered.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2273
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751, 851, 901
Event ID — 2098
Description Global hot spare assigned.
Severity OK / Normal / Informational
Cause and
Action
Cause: A user has assigned a physical disk as a global hot spare. This alert is for
informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2277
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2099
Description Global hot spare unassigned.
Severity OK / Normal / Informational
Cause and
Action
Cause: A physical disk that was assigned as a hot spare has been unassigned and is
no longer functioning as a hot spare. The physical disk may have been unassigned
by a user or automatically unassigned by Storage Management. Storage
Management unassigns hot spares that have been used to rebuild data. Once data
is rebuilt, the hot spare becomes a member of the virtual disk and is no longer
assigned as a hot spare. You need to assign a new hot spare to maintain data
protection in this situation. On the CERC SATA1.5/6 ch, and CERC SATA1.5/2s
controllers, if you use another application such as the BIOS to include a hot spare
in a virtual disk, then Storage Management unassigns the physical disk as a hot
spare.
Action: Although this alert is provided for informational purposes, you may need to
assign a new hot spare to the virtual disk.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
72