SNMP Trap
Numbers
901
Event ID — 2100
Description Temperature exceeded the maximum warning threshold.
Severity Warning / Non-critical
Cause and
Action
Cause: The physical disk enclosure is too hot. A variety of factors can cause the
excessive temperature. For example, a fan may have failed, the thermostat may be
set too high, or the room temperature may be too hot.
Action: Check for factors that may cause overheating. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and
examine whether the enclosure is located near a heat source. Make sure the
enclosure has enough ventilation and that the room temperature is not too hot.
See the physical disk enclosure documentation for more diagnostic information.
Related Alert
Information
Clear Alert Number: 2353
Related Alert Number: 2112
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1053
Event ID — 2101
Description Temperature exceeded the maximum warning threshold.
Severity Warning / Non-critical
Cause and
Action
Cause: The physical disk enclosure is too cool.
Action: Check if the thermostat setting is too low and if the room temperature is
too cool.
Related Alert
Information
Clear Alert Number: 2353
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1053
Event ID — 2102
Description Temperature exceeded the maximum failure threshold.
Severity Critical / Failure / Error
Cause and
Action
Cause: The physical disk enclosure is too hot. A variety of factors can cause the
excessive temperature. For example, a fan may have failed, the thermostat may be
set too high, or the room temperature may be too hot.
Action: Check for factors that may cause overheating. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and
73